Appliances for Measurement

Stack gas Analysis Appliance

Messtechnik Eheim Visit 01 LR, Messtechnik Eheim Visit 01, Messtechnik Eheim Visit 02 S
Used for the measurements of stack gas components and temperature.

  • Portable, electronic and automatic calibration feature
  • Has re-chargeable batteries, usable with batteries and city electricity
  • Comes with a probe with minimum length of 75 cm
  • Able to measure environmental temperature
  • Able to measure parameters of oxygen with minimum interval of %0 and %25, carbon monoxide with minimum interval of 0 ppm and 10000 ppm and temperature with minimum interval of  -40 ºC and +1000 ºC in stack gas

Thermal Camera

FLIR I50

  • Able to record the real image and thermal image simultaneously,
  • Able to record thermal images to external memory card and similar portable memories,
  • Reporting and USB computer interface software features,

for heat loss determination purpose.

Thermal Transmittance (U) Coefficient Measurement Appliance

TESTO 635-2 Humidity/Temperature/Absolute Pressure Measurement Appliance
Used for thermal transmittance coefficient measurement

  • Has a special temperature measurement probe that can measure several points on wall surfaces
  • Able to measure humidity and temperature on the other wall surface
  • Able to measure U in W/m2K value

Conductivity Meter

LUTRON YK-22 CT

  • Used for measurement of conductivity of several waters

    • Portable, electronic and battery-feed able
    • Able to measure water temperature and compensate temperature during measurement
    • Able to select scale automatically and manually
    • Able to show conductivity in minimum values of (mS/cm) and (TDS ppm)
    • Has the measurement interval of 0 mS/cm and 19.99 mS/cm
  • Steam Trap Testing Device

    TLV PT1 Pocket Trampan
    Used for controlling different types of steam traps

    • Portable
    • Able to control different types of steam traps

    Infrared Thermometer (Low Temperature)

    62 Fluke Mini Non-Contact Thermometer
    Used to measure the temperatures of hard-to-reach areas and moving areas such as rotor ovens,

    • Able to measure temperature values between -30ºC and +400ºC.
    • Portable, electronic and battery-feed able.
    • Light diffusion coefficient (e) can be adjustable between 0.10 and 1.00.

    Infrared Thermometer (High Temperature)

    576CF Fluke Precision Infrared Thermometer
    Used to measure the temperatures of hard-to-reach areas and moving areas such as rotor ovens,

    • Able to measure temperature values between +400ºC and +3000ºC.
    • Portable, electronic and battery-feed able.
    • Light diffusion coefficient (e) can be adjustable between 0.10 and 1.00.

    Vane (Fan) Type Anemometer

    LUTRON YK-80 AM
    Used for measuring gas or air speed or flow amount at suction mouth of air fans and exit mouth of exhaust canals.

    • Portable, electronic and battery-feed able.
    • Has probes in various diameters.
    • Able to do measurement and averaging in multiple environments.
    • Able to measure the speed between 0.25 m/sec and 20 m/sec.

     



    Electronic Thermometer

    51-52 FLUKE
    Used in temperature measurements by connection of several type of probes

    • Portable, electronic and battery-feed able.
    • Able to measure surface and environment temperature.
    • Able to hold measurement values on the monitor for hard-to-reach area measurements.

    Doppler Type Flow Meter

    Tokyo Keiki (Tokimec) UVH-2000 Model Ultrasonic Pulse Doppler Debimeter
    Used for measuring fluid amount from outside of pipelines through which dirty fluid flows.

    • Portable and electronic.

    Ultrasonic Flow Meter

    Tokyo Keiki (Tokimec) UFP-20 Model Portative Ultrasonic Debimeter
    Used for measuring fluid amount from outside of pipelines through which clean fluid flows.

    • Portable and electronic.
    • Can be set to start and stop automatically.
    • Has re-chargeable batteries, usable with batteries and city electricity.
    • Has a printer or a printer connection.
    • Has appliances to do measurements on pipes with diameters between13 mm and 1200 mm.
    • Able to measure temperatures between -40 ºC and +200 ºC.

    Electronic Relative Humidity Meter

    LUTRON HT-3006 HA

    Used for measuring environmental temperature and relative humidity in various areas

    • Portable, electronic and battery-feed able.
    • Able to show environmental dry thermometer temperature and relative humidity values simultaneously.
    • Able to measure temperature between -20 °C and +70 °C and relative humidity between %0 and %100.

    Manometer

    Messtechnik Eheim Visit 01 LR, Messtechnik Eheim Visit 01, Messtechnik Eheim Visit 02 S
    Used with pitot tube for measuring flow amount of the canals.

    • Can be used with pitot tube.
    • Portable and battery-feed able.

    Pressure values can be adjusted and/or selected in order to carry out accurate reading.

    Inclined Manometer

    Millennium Instruments Inc.

    Used during measuring oven internal pressure and similar very law-pressure values.

    Hotwired Anemometer (Appliance and its probe)

    Messtechnik Eheim Visit 01 LR, Messtechnik Eheim Visit 01, Messtechnik Eheim Visit 02 S
    Used for measuring flow amount of the canals through which air and low-pressure gases flow.

    • Portable, electronic and battery-feed able.
    • Comes with a probe with minimum length of 1,5 m ( this feature is not essential for building)
    • Able to measure speed between 0 m/sec and 20 m/sec and temperature between -20 °C and +70 °C for building and between -20 °C and +200°C for others.